Eine ältere Version des Dokuments wurde geladen! Beim Speichern wird eine neue Version des Dokuments mit diesem Inhalt erstellt. ====== UniversalSaftSwitch ====== UniversalSaftSwitch - your power under your control These simple devices are able to power on and off devices using a low current Relais. The deployed relais is able to switch current up to 16A@230VAC. The circuit itself takes 24VDC as input voltage and consumes about 8mA@24VDC=0.2W in idle mode and 25mA@24VDC=0.6W in switched mode. ===== Schematic & PCB ===== Version 1.0, Prototype ==== Schematic ==== {{:projekte:hausautomatisierung:uss-schematic.png?direct&800 |}} ==== PCB ==== {{:projekte:hausautomatisierung:uss-pcb.png?direct&200 |}} ====== First self-made Hardware Prototype ====== {{:projekte:hausautomatisierung:uss-upper.jpg?direct&200 |}} {{:projekte:hausautomatisierung:uss-lower.jpg?direct&200 |}} ===== Software ===== The software as well as schmematics are available on [[https://github.com/gurgelhals/UniversalSaftSwitch|Github]] The RS485 protocol follows the specifications of our [[projekte:hausautomatisierung:protokoll|RS-485 Hausbus Protokoll]] ===== Team ===== [[mitglieder:mirwi|Mirwi]] - Schematics, PCB Routing\\ [[mitglieder:mrks|Mrks]] - Prototyping\\ [[mitglieder:ralf|Ralf]] - Idea, Software, Schematics ===== Links ===== [[https://github.com/gurgelhals/UniversalSaftSwitch|Software & Schematics]]\\ [[https://secure.reichelt.de/index.html?&ACTION=20&AWKID=913503&PROVID=2084|Reichelt shopping cart]] What's the answer to life, the universe and everything? Dieses Feld bitte leer lassen:SpeichernVorschauAbbrechen Zusammenfassung projekte/hausautomatisierung/uss.1401823309.txt.gz Zuletzt geändert: 2014/06/03 19:21von ralf